This log records every deviation from the protocol written on 15 May 2026. It is append-only: entries are never deleted. If a critic asks “did you change your methodology mid-stream to get a particular result”, this is the answer.
Each entry gives what changed, why, the sections affected, who approved it and the impact on earlier work.
Amendment 2026-11-22-A1: honest self-description
- What changed: The review no longer describes itself as a “pre-registered systematic review” following “PRISMA 2020 reporting”. It is described as a structured critical appraisal of key studies and position papers; the protocol was written at project start and not registered with an external registry; a systematic database search is planned and has not been run.
- Why: The earlier wording described steps that had not been carried out. No database search was run, so neither “systematic review” nor “PRISMA” applies, and the protocol was never lodged with a registry.
- Sections affected: Protocol header and §0; every public description of the project.
- Approved by: Applied under the rebuild plan approved on 22 November 2026; individual sign-off by the lead reviewer pending.
- Impact on prior work: None on the appraisals themselves; the label changes. The planned search is listed on the Methods page.
Amendment 2026-11-22-A2: quality letters without modifiers; no letter for guidance
- What changed: Study-quality letters are reported exactly as the protocol rubric (§11) defines them, with no plus or minus modifiers. Guidance, consensus, regulatory and news documents (including both AAO white papers, the International Consensus Statement on OSA and the AADSM 2024 consensus) are no longer given a letter; their own evidence grading is reported instead.
- Why: The rubric does not define modifiers, and a study-quality letter designed for primary studies is not meaningful for a guidance document.
- Sections affected: Protocol §11; every study record.
- Approved by: Applied under the approved rebuild plan; individual sign-off by the lead reviewer pending.
- Impact on prior work: Ratings were rounded to the letter the rubric text supports, with the reason in each record. Notable changes: Papageorgiou 2025 A− → B (the rubric caps scan-only outcomes at B); Yu 2023 A− → B; Pirelli 2015 C+/B− → C; Rinchuse 2024 C → D (narrative review without explicit methods); Yoon 2020 (DOME) B− → C; Vinha 2016 B → C (case series); Magalhães 2024 B+ → B.
Amendment 2026-11-22-A3: direction (“camp”) tagging retired
- What changed: Studies and organisations are no longer labelled by “camp”. Where direction matters, the site says whether the authors conclude in favour of or against an intervention.
- Why: Team labels encourage reading evidence as a contest and are not part of any appraisal method.
- Sections affected: Protocol §9, §13, §14; reading list; reports.
- Approved by: Applied under the approved rebuild plan; individual sign-off by the lead reviewer pending.
- Impact on prior work: Labels removed from all published text; no rating depended on them.
Amendment 2026-11-22-A4: individuals policy enforced
- What changed: Commentary on named individuals was removed: a section on one researcher’s change of view, entries describing an online commenter and a device inventor, a note on a disciplinary matter, individual entries in the stakeholder map, and remarks about researchers’ continuing-education or credibility incentives that were not backed by a published disclosure. People now appear only as authors of cited work. Published conflict-of-interest declarations are still reported as published.
- Why: Protocol §1.3 already said the review would not adjudicate individuals. The earlier documents did not follow it.
- Sections affected: Reports on the AAO 2026 paper, the counter-position, key studies, the 2019–2026 comparison, the consensus-statement check, consolidated findings and study-level appraisal; the stakeholder map (now the Positions page, organisations only).
- Approved by: Applied under the approved rebuild plan; individual sign-off by the lead reviewer pending.
- Impact on prior work: The substantive findings about how AAO 2026 uses the International Consensus Statement are kept, described neutrally and tied to the source text. Objections first raised in online commentary are recorded without naming the commenter.
Amendment 2026-11-22-A5: blinding claim withdrawn
- What changed: The statement that tier assignment was “blind to camp” is withdrawn. Quality ratings use design, bias and outcome type and never the direction of the result, but they are made by a reader who can see each paper’s conclusions, so they are not blinded.
- Why: The earlier claim described a procedure that was not followed and is not achievable with a single reviewer.
- Sections affected: Protocol §2 (principle 3), §13.
- Approved by: Applied under the approved rebuild plan; individual sign-off by the lead reviewer pending.
- Impact on prior work: None on ratings; the description changes.
Amendment 2026-11-22-A6: AI assistance and verification status disclosed
- What changed: Every page states that content was drafted with AI assistance (Claude, Anthropic) under the lead reviewer’s direction. Every source record shows whether its citation has been verified, whether it was appraised from the full text, and whether its quotations have been checked by a person. DOI and PubMed links are shown only for verified citations. Pages show whether the lead reviewer has signed them off.
- Why: Readers need to know how the content was produced and what has been checked.
- Sections affected: All pages; About; Methods.
- Approved by: Applied under the approved rebuild plan; individual sign-off by the lead reviewer pending.
- Impact on prior work: Several earlier “verified verbatim” labels were replaced with per-source status.
Amendment 2026-11-22-A7: scope additions
- What changed: New questions on whether pulling the front teeth back shrinks the airway, extractions and facial profile, the AGGA appliance, the risks of expansion without skeletal need, mouth taping, preformed myofunctional appliances (Myobrace-type) and the soft-diet/jaw-size hypothesis; explainers on how extraction decisions are made, what causes sleep apnea and how to read airway studies; a glossary and a page for patients and parents.
- Why: These are claims readers meet frequently, and the explainers supply background the question pages rely on.
- Sections affected: Protocol §1.2 and §5 (scope).
- Approved by: Applied under the approved rebuild plan; individual sign-off by the lead reviewer pending.
- Impact on prior work: None on existing answers.
Amendment 2026-11-22-A8: factual corrections from the rebuild plan
- What changed:
- The Vivos severe-OSA 510(k) clearance was announced on 29 November 2023, not in 2024. A separate clearance for children aged 6–17 was announced on 18 September 2024. Both are documented through AASM news reports of company announcements; the FDA database entries have not been checked.
- The mewing page no longer says the sutures are “functionally fused by late adolescence”. Suture maturation varies widely; most adults’ sutures are fused but not all (Angelieri 2013, 2017). The conclusion that tongue posture has no demonstrated skeletal effect in adults is unchanged.
- The adult MARPE trial: 6 of 20 treated participants were not analysed (3 lost to follow-up, 3 expansion failures), not 3. The 55% and 25% figures count all six as non-responders and are our calculation, not the paper’s.
- The figure “~30% spontaneous resolution of childhood OSA (Bixler 2016)” was removed: Bixler 2016 reports 52.9% remission of AHI ≥2 by adolescence, with 40% loss to follow-up, and the only figure near 30% in that paper concerns persistent snoring. The CHAT trial’s watchful-waiting figure is used instead: polysomnography normalised in 46% over seven months, against 79% after adenotonsillectomy.
- Why: Errors identified in the rebuild plan and confirmed against the sources.
- Approved by: Applied under the approved rebuild plan; individual sign-off by the lead reviewer pending.
- Impact on prior work: Affected pages and reports corrected and annotated.
Amendment 2026-11-22-A9: corrections found by citation verification
When every citation was checked against PubMed, publisher pages and the documents themselves, the following errors in the earlier work were found and corrected. We list them plainly because a reference that corrects itself in public is more useful than one that appears never to err.
- What changed:
- Misattributed trial. The adult MARPE “multi-center prospective controlled trial” cited throughout as “Yoon et al., 2021” is Brunetto DP et al., Progress in Orthodontics 2022;23(1):3. The author list we gave belonged to a different paper. Statements describing “Stanford/UCLA research-group authorship” and related conflict-of-interest speculation were wrong and have been removed; the paper’s declared conflict is that one author holds a patent on the expander used. Its “85% success rate” refers to successful skeletal expansion, not to sleep improvement. The record is now
brunetto-2022(the old address redirects). - Non-existent citation. “Singh & Olmos 2023, Int J Environ Res Public Health” does not exist as cited. The 46% / 28% figures for the DNA appliance come from Dao N et al., Pathophysiology 2023;30(2):199–208, a retrospective manufacturer-database study without a control group. The record is now
dao-2023(the old address redirects). - Finding reported backwards. Gu 2019 was described as showing “significant upper airway volume increase” with functional appliances. It found no significant airway change on MRI in either group and no change in sleep questionnaire scores, and it did not measure volume. The question page on functional appliances changed its answer from “Supported in specific cases” to “Mixed evidence” as a result.
- Misquotation. The AADSM 2024 consensus was reported, through a secondary source, as saying “maxillary constriction is not a factor that contributes to pediatric OSA”. The document says maxillary constriction “is suggested to play a potential role in the pathophysiology of OSA”. The document has now been read in full.
- Other corrections: Larsen 2015 diagnoses were confirmed by polysomnography (not unverified codes) and its estimate is now reported (OR 1.14, 95% CI 0.96 to 1.37); Zaghi 2016 included 518 patients, not 528; the AAP 2024 document is a clinical report on ankyloglossia and breastfeeding, not breastfeeding guidelines, and its exact wording is now quoted; Villa 2015’s 10-year group appears to be a separate earlier-treated group, not 35% retention of the 40; the DOME study reported AHI for 43 of 75 patients and was published in 2020; the Hu 2015 subgroup counts we gave are not in the paper; the company endpoint behind the Vivos severe-OSA clearance is “at least one severity class or at least 50%” improvement; several unverified details (premolar agenesis prevalence, a planned trial against CPAP, “53 pages”, “based on 51 RCTs”) were removed or marked unverified.
- An earlier objection reversed. Our earlier analysis endorsed an online objection that AAO 2026 misused Bixler 2016 on natural resolution. Bixler’s own conclusion matches the AAO’s statement, so that objection is no longer endorsed.
- Misattributed trial. The adult MARPE “multi-center prospective controlled trial” cited throughout as “Yoon et al., 2021” is Brunetto DP et al., Progress in Orthodontics 2022;23(1):3. The author list we gave belonged to a different paper. Statements describing “Stanford/UCLA research-group authorship” and related conflict-of-interest speculation were wrong and have been removed; the paper’s declared conflict is that one author holds a patent on the expander used. Its “85% success rate” refers to successful skeletal expansion, not to sleep improvement. The record is now
- Why: Citation verification (PLAN rules E1–E3).
- Approved by: Applied under the approved rebuild plan; individual sign-off by the lead reviewer pending.
- Impact on prior work: Every affected question page, study record, report and the Positions page was corrected; each correction is noted where it appears.
Amendment 2026-11-22-A10: critical appraisal of every source and an enforced evidence bar
-
What changed:
- Every source now carries a structured critical appraisal: how much of it we read (full text, abstract only, or a secondary description), its design (comparison group, randomisation, prospective conduct, registration, blinded outcome assessment), sample size and losses, follow-up, which named confounders it did and did not address, graded problems (critical, major, minor), declared funding and conflicts, verifiable facts about the journal (MEDLINE indexing and any documented concern), whether the authors’ conclusion follows from their data, and an overall confidence in its main result. Fifty of the 101 sources have now been read in full (22 before), the additional full texts obtained from PubMed Central, publisher open access and author repositories. A list of sources still rated from the abstract, with their DOIs, is kept for the lead reviewer to supply PDFs.
- Fixed caps: abstract-only or secondary appraisal caps confidence at low and the quality letter at C; any critical problem caps confidence at low; a scan-only outcome caps confidence at moderate; guidance, regulatory and news items are not assessable as evidence of effect. Quality letters were re-derived on this basis. Fourteen letters fell: thirteen sources rated B (or A) from their abstracts are now C until read in full (Antoszewska-Smith 2017, Camacho 2017, Konstantonis 2018, Lo Giudice 2018, Magalhães 2024, Meksukree 2025, Mohammed 2020, Orabi 2021, Papageorgiou 2019, Villa 2015, Yu 2023, Zaghi 2016; Peppard 2000 A → C), and Brunetto 2022 B → C after the full text showed a per-protocol analysis with no reported between-group test.
- An evidence bar for verdicts, checked automatically before publication. Each question names its carrying studies and states why the bar is or is not met. “Supported” needs two independent carrying studies (or one systematic review of controlled studies) read in full, at moderate or high confidence, with outcomes that measure the claim and no conflicting evidence of similar quality; “Supported in specific cases” needs the same for a named group; “Mixed” needs quality studies in conflict; “Not supported” means the proponents’ evidence fails the bar and the page must say whether quality evidence actively contradicts the claim; everything else is “Not enough evidence”. Certainty may not exceed the best carrying-study confidence. Guidance summaries are worded as what bodies recommend.
- The standard is symmetric: it applies equally to studies and guidance favouring mainstream orthodontic positions and to those favouring airway-focused positions. The journal is treated as a flag prompting closer reading, never as a score.
-
Verdict and certainty changes (old → new):
Question Old New Reason Tonsils and adenoids first? Supported, moderate Supported in specific cases, moderate Two randomised trials (CHAT, PATS) meet the bar only for otherwise healthy children with enlarged tonsils and non-severe disease, and not for cognitive outcomes, where both were null. Expansion for childhood sleep apnea Supported in specific cases, low Not enough evidence, very low Positive studies are uncontrolled; the controlled pooled estimate found no effect of expansion alone; none read in full. Functional appliances and the airway Mixed, low Not enough evidence, very low No study reaches moderate confidence, so no conflict between quality studies can be shown. Myofunctional therapy Mixed, low Not enough evidence, very low The main review, read in full, pools before-after changes from mostly uncontrolled studies. Pulling the front teeth back and the airway Mixed, low Not enough evidence, low All studies low confidence: retrospective scans at critical risk of bias; the only breathing trial an underpowered pilot. Jaw advancement surgery (MMA) Supported, low Not enough evidence, low Evidence is pooled uncontrolled case series read in abstract; effects are large but the bar is not met. Oral appliances for adults Supported, moderate (guidance summary) Not enough evidence, no certainty (scoping) The answer rested on a guideline alone; guidance cannot carry an effectiveness verdict, and the trials are not yet appraised. Soft diets and small jaws Supported in specific cases, low Not enough evidence, low Population and animal studies read only in abstract; the airway link is a narrative argument. Tongue-tie release and sleep Not supported, low (guidance summary) Not enough evidence, no certainty (guidance summary) Guidance cannot carry an effectiveness verdict, and the primary studies have not been appraised. Airway marketing claims Supported, low Not supported, low Restated as the marketing claims themselves; the evidence cited for them fails the bar, and the page now also says that reassurances of proven safety go beyond the evidence. Can research settle this? Mixed, no certainty Not enough evidence, no certainty A question about research methods; no study can meet the bar either way. Avoiding extractions to protect the airway Not supported, low Not supported, very low No carrying study above low confidence; long-term safety not shown either. Expansion without a narrow jaw Not supported, low Not supported, very low No study of this use; closest evidence abstract-only. Can a scan show sleep apnea? Not supported, moderate Not supported, low No diagnostic-accuracy study appraised; certainty capped by the carrying studies. Screening in orthodontics Supported, low Supported (guidance summary), no certainty Guidance summaries carry no certainty rating; “Supported” means the recommendation is consistent, not that screening is shown to help. Reliability of the AAO white papers Mixed (structured appraisal) Mixed (guidance summary) Reclassified as an appraisal of documents. -
Corrections found by reading full texts: Larsen 2015 identified OSA from diagnosis codes validated against polysomnography or CPAP records, not from polysomnography in every record as we had said; Papageorgiou 2025 labels its evidence “moderate” although its own risk-of-bias assessment rates every included study at critical risk for selection; Brunetto 2022 reports no between-group test of change despite its abstract’s statement that the groups differed; Kim 2026’s conclusion that simulated arch constriction “does not affect respiratory function” is stronger than its pilot can support by its own power estimate; Dao 2023 required a follow-up sleep test for inclusion and mixed test types and scoring rules.
-
Why: The lead reviewer asked that a claim be given a position only when quality studies truly support it, and that each study’s quality, venue, confounders and errors be weighed rather than its conclusion. Most sources had been rated from abstracts and verdicts had no enforced bar.
-
Sections affected: Protocol §10 and §11 (as applied), every study record, every question page, the three explainers, the Methods page.
-
Approved by: Requested by the lead reviewer; individual sign-off of each page pending (all pages remain unsigned).
-
Impact on prior work: Sixteen answers changed verdict, certainty or evidence basis (table above). No answer moved towards a firmer conclusion except where the claim was restated.