What this site is
A structured critical appraisal of key studies and position papers. A systematic database search is planned and has not been run. This is not a systematic review, and it does not follow PRISMA reporting, because the search and screening steps those terms require have not yet been carried out.
The protocol was written at project start (15 May 2026). It was not registered with an external registry. Every later change to it is recorded, with a date and a reason, in the amendments log.
Content is drafted with AI assistance (Claude, Anthropic) under the direction of the lead reviewer, who reviews it. A page is marked “signed off” only after the lead reviewer has personally read and approved it. See how AI is used.
What has and has not been done
These figures are computed from the site's data each time it is built.
- sources in the evidence library
- 101
- studies with a formal risk-of-bias tool applied
- 24
- of those appraised from the full text
- 11 of 24
- sources read in full (all types)
- 50 of 101
- citations checked against a bibliographic record
- 101 of 101
- sources whose quotes a person has checked
- 0 of 101
- pages signed off by the lead reviewer
- 0 of 31
- systematic database searches run
- 0
Risk-of-bias tools applied to 24 studies; 11 of those from the full text. The tools used depend on design: Cochrane RoB 2 for randomised trials, ROBINS-I for non-randomised intervention studies, the Newcastle–Ottawa Scale for observational studies, AMSTAR-2 for systematic reviews and the JBI checklist for case series. Guidance documents were assessed against AGREE II principles in a structured but informal way.
Ratings marked provisional were made from an abstract or from another document's description of the study, and may change once the full text is read. Since 22 November 2026 every source also carries a structured critical appraisal, and an abstract-only appraisal can never give a study more than low confidence. Direct quotations were extracted with AI assistance; each source record says whether a person has checked them against the original.
How we rate a study
Each study gets a study quality letter from the protocol rubric. It uses the design, the risk of bias, the size, the length of follow-up, conflicts of interest and the type of outcome, and never the direction of the result. Ratings are made by a reader who can see the paper's conclusions, so they are not blinded.
- Letters are used exactly as the rubric defines them, with no plus or minus modifiers, because the rubric does not define any.
- Studies whose only outcomes are scan or X-ray measurements are capped at B, however well designed.
- Industry funding is recorded but does not by itself lower a grade, unless the conflict is direct (for example, a study funded by the maker of the device it tests).
- The protocol also defines a top grade, “S” (definitive), requiring a large, pre-registered, independently funded trial or cohort with long follow-up, replicated elsewhere. No study in this field currently meets it.
- Guidance, regulatory and news sources are not given a letter. Where a guideline grades its own evidence, we report that grading instead.
- A study we have read only in abstract is capped at C, because bias cannot be judged from an abstract.
How we appraise a study
A conclusion in a paper is not evidence that the conclusion is right. For every source we read as much of the paper as we can obtain (the full text where it is openly available; otherwise the abstract) and record, on the source's page:
- How much we read: the full text, the abstract only, or only another document's description of it. We record only what we actually read; if we could not get the full text, we say so and do not guess at the methods.
- The design: whether there was a comparison group, whether treatment was assigned at random, whether the study was planned in advance (prospective), whether its plan was registered before the results were known, and whether the people measuring the results knew who had which treatment.
- Size and losses: how many people were in each group, whether the authors calculated how many they needed, and how many dropped out or were left out of the results.
- Other explanations: which of the factors that commonly distort studies in this field were dealt with and which were not. We check them by name: age and growth, body weight, sex, tonsil and adenoid size, a blocked nose, how severe the problem was at the start, the tendency of childhood sleep apnea to improve with growth, regression to the mean, head and body posture and breathing phase during a scan, tongue position, night-to-night variation in sleep tests, home tests versus laboratory sleep studies, and other treatments given at the same time.
- Problems, each graded critical, major or minor and written so that a reader can check it against the paper: for example, leaving out the people for whom treatment failed, no comparison group, scan results presented as clinical benefit, unblinded scoring, many outcomes without correction, outcomes that differ from the registered plan, a small study that found nothing being presented as proof of no effect, numbers that do not add up, or conclusions stronger than the data.
- Funding and declared conflicts of interest, as stated in the paper.
- Whether the authors' own conclusion follows from their own data: yes, partly, no, or cannot tell.
Confidence, and how it differs from the quality letter
The quality letter describes the kind of study, using the rubric above. Confidence is our overall judgement of whether this study's main result is right and means what the authors say, after reading it for the problems listed above: high, moderate, low, very low, or not assessable. Two randomised trials can have the same letter and different confidence if one left out its treatment failures. Fixed rules limit how high confidence can go:
- A study read only in abstract, or only through another document, is capped at low.
- Any critical problem caps confidence at low.
- A study whose main outcome is a scan or X-ray measurement is capped at moderate for questions about anatomy, and cannot carry an answer about sleep or breathing at all.
- Guidance documents, regulatory notices and news items are not assessable as evidence of effect. They can show what a body recommends or what a regulator did, never on their own whether a treatment works.
A small study that finds no difference is weak evidence that there is no difference, and we say so. Absence of evidence is recorded as absence of evidence.
Where a study was published
We treat the journal as a flag, not a score. For each source we record facts we can check: whether the journal is indexed in MEDLINE, and anything documented that is worth a reader knowing, such as a mega-journal model that reviews for technical soundness rather than importance, an unusually short interval between submission and acceptance printed on the paper, a practitioner association's journal, or a publisher's documented mass retractions. We do not use impact factors. A flag is a reason to read the paper more closely and is shown to readers; it never lowers the rating of a sound study, and a prestigious journal never raises the rating of a weak one.
How we reach an answer
Each question page states a claim as people make it and gives one of six answers. The label always comes with an icon shape and the words, so it does not rely on colour.
- Supported Quality studies show the claim is true
- Supported in specific cases Quality studies show it for a named group only
- Mixed evidence Quality studies point in different directions
- Not enough evidence The bar is not met: the default answer
- Not yet assessed Studies exist that we have not yet appraised, so we give no answer of our own
- Not supported No quality evidence supports the claim
The evidence bar
We take a position on a claim only when quality studies support it. Each question page names the specific sources its answer rests on (“carrying studies”) and says in a sentence or two why the bar is or is not met. The site's checks refuse to publish a page whose answer does not clear its bar.
- Supported needs at least two independent carrying studies, or one systematic review of controlled studies, that we have read in full and rate at moderate or high confidence, whose outcomes measure the thing claimed (sleep-study or symptom outcomes for claims about sleep apnea or breathing; scan outcomes only for purely anatomical claims), with no conflicting evidence of similar quality.
- Supported in specific cases needs the same, met only for a defined group of patients, and the page names that group.
- Not supported means no quality evidence supports the claim: the evidence its proponents rely on fails the bar. Each such page says separately whether quality evidence actively contradicts the claim, or whether the opposite simply has not been shown either. It never means “proven false” or “proven safe”.
- Mixed evidence needs quality studies (moderate confidence or better) that point in different directions.
- Not enough evidence is everything else, and it is the default whenever the bar is not met.
- Questions about what guidance says or who may legally diagnose are marked as guidance summaries. Their answers are worded as what professional bodies recommend, not as proven effects, and they cite the documents themselves.
The same bar applies to every side. It applies equally to studies and guidance that favour mainstream orthodontic positions and to those that favour airway-focused positions. A reassuring study with a critical flaw carries no more weight than a worrying one with the same flaw. When the bar was introduced in November 2026, several answers changed to “Not enough evidence”, including answers on both sides of the debate; every change is listed in the amendments log (A10).
Alongside the answer we give a certainty (high, moderate, low or very low), modelled on GRADE: how confident we are that further research would not change the answer. Formal GRADE assessment requires the systematic search that has not yet been run, so every certainty rating is shown as provisional. Certainty can never exceed the best confidence among the carrying studies, and it is low or very low when they were read only in abstract. Some questions (for example, who is legally allowed to diagnose) are not evidence-of-effect questions and carry no certainty rating.
Before giving an answer, each page sets out the strongest case for the claim and the strongest case against it, with equal space, and says what evidence would change the answer. Each page also states its evidence basis: a structured appraisal of studies, a summary of professional guidance, or a scoping overview.
Outcomes that matter
Results from sleep studies (polysomnography or home sleep tests), symptoms, daytime sleepiness and quality of life rank above measurements taken from scans, such as CBCT airway volume or cephalometric airway width. A wider airway on a scan does not show that breathing during sleep has improved. Wherever an answer rests on scans alone, it is labelled as a surrogate.
Limitations of this review
- No systematic search yet. The sources are the documents at the centre of the current debate and the studies they cite or omit. Relevant studies may be missing.
- One reviewer, assisted by AI. Screening and appraisal have not been duplicated by a second independent reviewer. Ratings involve judgement and are not blinded.
- Some appraisal is from abstracts or secondary descriptions (51 of 101 sources); these are marked provisional and capped at low confidence. Some full texts were read through an automated text extractor rather than as the published PDF; the source page says so where it matters.
- No meta-analysis. Numbers come from the cited studies. Where we have recalculated a figure (for example, counting participants who were not analysed), the page says so.
- Disclosures incomplete. The lead reviewer's full disclosure statement is being prepared; see About.
Planned work
- Run a real systematic search for three questions first: extractions and retraction, expansion in children, and skeletal expansion in adults. Register that protocol on OSF before running it, and publish the search strings, dates, hit counts and a PRISMA flow diagram.
- Add a second human reviewer for screening and risk-of-bias assessment.
- Name advisory reviewers: a sleep physician, a paediatric ENT surgeon, a methodologist, and a clinician who practises orthodontics focused on the airway.
- Invite adversarial review from both sides of the debate and publish the responses in full.
- Set quarterly dates to review each page again, and log every update.
- Move to a custom domain.