Systematic review / meta-analysis
Mohammed 2020
Mohammed H, Čirgić E, Rizk MZ, Vandevska-Radunovic V. Effectiveness of prefabricated myofunctional appliances in the treatment of Class II division 1 malocclusion: a systematic review. European Journal of Orthodontics. 2020;42(2):125-134.
Study summary
- Study quality
- Weak (grade C)Provisional
- Confidence
- Design
- Systematic review / meta-analysis
- Year
- 2020
- Outcome type
- Scan-based (surrogate)
- Size
- 3 RCTs and 3 non-randomised studies
- Population
- Children and adolescents with Class II division 1 malocclusion
- Intervention or topic
- Prefabricated myofunctional appliances vs activators or no treatment
Scan or measurement results, not sleep study or symptom outcomes.
- Citation verified (yes) Author, year and title were confirmed against a bibliographic record or the publisher.
- Provisional (not yet) Rated from the abstract or a secondary description; the rating may change once the full text is read.
- Quotes AI extracted (not yet) Any direct quotation from this source has not yet been checked by a person against the original.
What it found
Short term, activators corrected overjet about 1.1 mm more than prefabricated appliances; long term, no significant difference. The main advantage of prefabricated appliances was cost.
Limits of this source
2- Low quality evidence
- No sleep outcomes
Critical appraisal
How we appraise Our confidence in the result
Flaws in the study could easily explain the result.
How we read it
Abstract only. We read the abstract only.
Design
- Control groupControl group — A comparison group that does not get the treatment being tested.
- Yes
- RandomisedRCT — A study in which people are assigned to treatments by chance, so the groups are comparable.
- Not reported
- ProspectiveProspective study — A study that sets out its plan first and then follows people forward in time.
- Not reported
- Pre-registeredPre-registration — Publishing a study's plan, including its main outcome, before the results are known.
- Not reported
- Blinded outcome assessmentBlinding — Keeping the people who measure the results from knowing who had which treatment.
- Not reported
- Sample size
- Systematic review of randomised and non-randomised studies of preformed appliances.
- Follow-up
- Not reported
Problems 2
- Major: Full text not read: randomisation, blinding, attrition, analysis and selective reporting could not be checked.
- Minor: Dental outcomes only.
Does the authors' conclusion follow from their data?
Cannot tell. Cannot be judged from the abstract.
ConfoundersConfounding — When something else explains a link between a treatment and an outcome.: other explanations for the result
Accounted for
None
Not accounted for
- not assessable
Funding, conflicts and publication
- Funding
- Not recorded
- Conflicts of interest
- Not recorded
- Where it was published
- European Journal of Orthodontics. Indexed in MEDLINE.
Quality grade
How we rate studies- Study quality
- Study quality: Weak (grade C)
Grade C (Weak) on the protocol rubric. Provisional.
- Appraisal tool
- Review used Cochrane RoB and ROBINS-I; AMSTAR-2 not applied by us
- Judgement
- Rated from the abstract only (full text not obtained), 22 November 2026: quality C (previously B), confidence low. Main problem: Full text not read: randomisation, blinding, attrition, analysis and selective reporting could not be checked. Earlier note: Registered review (PROSPERO CRD42018108564); low-quality evidence; measurement outcomes. Provisional: rated from the PubMed abstract only; full text not read.