Case series

Dao 2023

Dao N, Cozean C, Chernyshev O, Kushida C, Greenburg J, Alexander JS. Retrospective analysis of real-world data for the treatment of obstructive sleep apnea with slow maxillary expansion using a unique expansion dental appliance (DNA). Pathophysiology. 2023;30(2):199-208.

Study summary

Study quality
Weak (grade C)
Confidence
Design
Case series
Year
2023
Outcome type
Sleep study or symptoms
Size
87 adults
Population
Adults with OSA treated with the DNA appliance, from a manufacturer's database
Intervention or topic
DNA appliance (Vivos); mean treatment 14.8 months
  • Citation verified (yes) Author, year and title were confirmed against a bibliographic record or the publisher.
  • Appraised from the full text (yes)
  • Quotes AI extracted (not yet) Any direct quotation from this source has not yet been checked by a person against the original.

What it found

Mean AHI fell from 22.5 to 12.3 events/h (46%) and 24 of 87 patients (28%) reached AHI below 5. Forty-one per cent also received adjunct treatments (myofunctional therapy, CPAP or tissue releases), and 6 patients (6.9%) developed an open bite.

Limits of this source

4
  • No control group.
  • Mostly home sleep tests.
  • Many patients had other treatments at the same time, so the appliance's own effect cannot be isolated.
  • Manufacturer database and author relationships with the manufacturer.

Critical appraisal

How we appraise
Our confidence in the result

The result cannot be relied on; serious flaws could fully explain it.

How we read it

Full text. We read the full paper.

Design

Control groupControl group — A comparison group that does not get the treatment being tested.
No
RandomisedRCT — A study in which people are assigned to treatments by chance, so the groups are comparable.
No
ProspectiveProspective study — A study that sets out its plan first and then follows people forward in time.
No
Pre-registeredPre-registration — Publishing a study's plan, including its main outcome, before the results are known.
No
Blinded outcome assessmentBlinding — Keeping the people who measure the results from knowing who had which treatment.
Not reported
Sample size
87 adults from the manufacturer's practice database (38 dentists); selection required pre- and post-treatment AHI at least 6 months apart. The number of treated patients without follow-up data is not reported.
Follow-up
6 to 24 months of wear

Problems 4

  • Critical: No control group, and inclusion required a follow-up sleep test, so patients who stopped or did not improve may be missing (selection on outcome).
  • Major: Sleep tests of different types and scoring rules before and after treatment.
  • Major: Study originated from a regulator's request for real-world data; several authors hold advisory or funded roles with the manufacturer.
  • Major: Conclusions go well beyond the data ("permanent anatomic/functional solution", "highly likely that these changes will be sustained").

Does the authors' conclusion follow from their data?

No. A 46% mean AHI fall in a selected, uncontrolled database sample does not support claims of permanence or of equivalence to other treatments.

ConfoundersConfounding — When something else explains a link between a treatment and an outcome.: other explanations for the result

Accounted for

  • some co-interventions (7 excluded for surgery or switching device)

Not accounted for

  • weight change
  • regression to the mean
  • home test versus laboratory polysomnography (both used)
  • scoring rule (3% or 4% hypopnea criteria both used)
  • adjunctive myofunctional therapy and other co-interventions at the dentist's discretion
  • patients who stopped treatment or had no repeat test

Funding, conflicts and publication

Funding
No external funding declared. Data from the manufacturer's database; several authors had advisory, consulting or research-funding relationships with the manufacturer.
Conflicts of interest
No external funding. Authors declare membership of the manufacturer's medical advisory board, regulatory consulting for it, and research funding on its products.
Where it was published
Pathophysiology. Not indexed in MEDLINE. Some concern: Published by MDPI. Received 4 January 2023, accepted 28 April 2023.

Quality grade

How we rate studies
Study quality
Study quality: Weak (grade C)

Grade C (Weak) on the protocol rubric.

Judgement
Appraised from the full text, 22 November 2026: quality C, confidence very-low. Main problem: No control group, and inclusion required a follow-up sleep test, so patients who stopped or did not improve may be missing (selection on outcome). Earlier note: Graded C: a retrospective series without a control group, mostly home sleep tests (under 5% polysomnography), with 41% of patients also receiving other treatments, drawn from the manufacturer's database. Several authors had advisory, consulting or funded-research relationships with the manufacturer. Earlier versions of this site cited these figures as “Singh & Olmos 2023”; no such paper exists.

Questions that cite this

2

Also cited in