Non-randomised trial
Brunetto 2022
Brunetto DP, Moschik CE, Dominguez-Mompell R, Jaria E, Sant'Anna EF, Moon W. Mini-implant assisted rapid palatal expansion (MARPE) effects on adult obstructive sleep apnea (OSA) and quality of life: a multi-center prospective controlled trial. Progress in Orthodontics. 2022;23(1):3.
Study summary
- Study quality
- Weak (grade C)
- Confidence
- Design
- Non-randomised trial
- Year
- 2022
- Outcome type
- Sleep study or symptoms
- Size
- 32 enrolled (20 intervention, 12 control); 24 analysed (14 intervention, 10 control)
- Population
- Non-obese adults (BMI ≤35) with OSA (home sleep test AHI >5) and a skeletally narrow upper jaw
- Intervention or topic
- MARPE without osteotomy versus no treatment; outcomes at 6 months
- Citation verified (yes) Author, year and title were confirmed against a bibliographic record or the publisher.
- Appraised from the full text (yes)
- Quotes AI extracted (not yet) Any direct quotation from this source has not yet been checked by a person against the original.
What it found
Among the 14 treated participants who were analysed, the paper reports a 65.3% average fall in AHI on a home sleep test (the reported group means, 28.75 to 11.45 events/h, imply about 60%), with improved sleepiness and sleep-related quality of life; the 10 analysed controls did not change. Six of the 20 treated participants were not analysed: 3 were lost to follow-up and 3 had an unsuccessful expansion. The paper's “85% success rate” is the rate of successful skeletal expansion (17 of 20), not of sleep improvement.
Limits of this source
6- Six of 20 treated participants (30%) were not analysed. Counting all six as non-responders, 11 of 20 (55%) had at least a 50% fall in AHI and 5 of 20 (25%) reached AHI below 5. These two figures are our calculation, not the paper's; the paper reports 78.5% and 35.7% of the 14 analysed.
- Not randomised; controls were volunteers who declined treatment, matched only on AHI.
- Home sleep testing (type III monitor, no EEG), which tends to read lower than laboratory polysomnography.
- About six months of follow-up: durability is unknown.
- The headline 65.3% does not match the reported group means (about 60%), and the calculation is not explained.
- One author holds a patent on the expander studied.
Critical appraisal
How we appraiseFlaws in the study could easily explain the result.
Full text. We read the full paper.
Design
- Control groupControl group — A comparison group that does not get the treatment being tested.
- Yes
- RandomisedRCT — A study in which people are assigned to treatments by chance, so the groups are comparable.
- No
- ProspectiveProspective study — A study that sets out its plan first and then follows people forward in time.
- Yes
- Pre-registeredPre-registration — Publishing a study's plan, including its main outcome, before the results are known.
- No
- Blinded outcome assessmentBlinding — Keeping the people who measure the results from knowing who had which treatment.
- Yes
- Sample size
- 20 treated and 12 untreated adults enrolled; 14 treated and 10 controls analysed. Power calculation reported (8 per arm to detect a 9.5-event change in AHI). 6 of 20 treated (30%) not analysed: 3 lost to follow-up and 3 whose expansion failed.
- Follow-up
- About 6 months after the last activation
Problems 6
- Critical: Per-protocol analysis: the 3 participants whose expansion failed and the 3 lost to follow-up were dropped from the treated group, so the reported 65% AHI reduction describes successful completers only.
- Critical: The paper reports only within-group tests (Wilcoxon) and a baseline between-group comparison; no between-group test of the change at follow-up is reported, although the abstract states the groups differed.
- Major: Not randomised; the control group was made up of people who declined conventional OSA treatment, and controls had no CBCT.
- Major: Outcome was a single type III home sleep test at each time point (automatic scoring, then manual editing by a sleep professional blinded to group); no sleep staging, and night-to-night variability is not addressed.
- Major: No trial registration is reported, so the outcomes cannot be checked against a pre-specified plan.
- Minor: One author holds a patent on the expander tested (declared).
Does the authors' conclusion follow from their data?
Partly. The completers improved on home sleep tests and questionnaires, but the conclusion that MARPE "promoted important respiratory benefits" goes beyond a per-protocol, non-randomised comparison with no reported between-group test of change.
ConfoundersConfounding — When something else explains a link between a treatment and an outcome.: other explanations for the result
Accounted for
- BMI (non-obese only; BMI and neck circumference unchanged)
- baseline severity (controls matched on AHI)
Not accounted for
- self-selection of controls (adults who declined standard treatment)
- sex imbalance between arms (6/8 v 6/4 male/female)
- night-to-night variability of a single home test at each time point
- regression to the mean
- co-interventions after expansion (fixed appliances) not described for the sleep test timing
Funding, conflicts and publication
- Funding
- Partly funded by CAPES (Brazil). Declared conflict of interest: one author holds a patent on the expander used.
- Conflicts of interest
- Partly funded by CAPES (Brazil). One author declares a patent on the Maxillary Skeletal Expander used in the study.
- Where it was published
- Progress in Orthodontics. Indexed in MEDLINE. Published by SpringerOpen. Received 2 August 2021, accepted 17 December 2021.
Quality grade
How we rate studies- Study quality
- Study quality: Weak (grade C)
Grade C (Weak) on the protocol rubric.
- Appraisal tool
- ROBINS-I
- Judgement
- Appraised from the full text, 22 November 2026: quality C (previously B), confidence low. Main problem: Per-protocol analysis: the 3 participants whose expansion failed and the 3 lost to follow-up were dropped from the treated group, so the reported 65% AHI reduction describes successful completers only. Earlier note: Graded B: a controlled study with sleep-test and symptom outcomes, but not randomised, small, and about 6 months long. Serious risk of confounding (controls were volunteers who declined treatment, matched only on AHI) and of bias from missing data: 6 of the 20 treated participants were not analysed. The home sleep test scorer was blinded to group. Earlier versions of this site called this trial “Yoon 2021” and described “Stanford/UCLA authorship”; both were wrong.
Questions that cite this
5Can removable appliances (DNA/Vivos, Homeoblock, ALF) grow an adult jaw or treat sleep apnea?
Does mewing or orthotropics change the face or airway?
How reliable are the AAO white papers on airway?
Which “airway orthodontics” marketing claims go beyond the evidence?
Also cited in
- How to read an airway study Explainer